fbpx

Polo – Modular Twist & Lock IP65 Bulkhead

Multi-Function

CCT Switchable

The CCT switch is located on the front of the LED board, with 3 positions corresponding to 3000K, 4000K and 5000K.

Wattage Switchable

It is wattage switchable between 9W, 12W and 15W. The 3-position switch is located on the back of the LED tray.

Sensor & Emergency

Sockets of plug-in sensor and emergency modules are on the side of the LED driver.

Plug-in Sensor

1. Configure the sensor to the desired setting using the dip switches. The sensor can be Dusk to Dawn & Corridor Function.

Order Code: MWS-DC

2. Snap and remove the rectangle covering piece on the LED tray.

3. Insert the sensor into the holding bracket on the back of the LED tray. Ensure the front of the sensor is visible through the rectangular window.

4. Connect the sensor to the socket on the driver marked ‘sensor’.

Plug-in Emergency Module

1. Place the Emergency Module in the slot on the base of the fitting, as shown in the diagram above.

Order Code: EMDD02 (standard), EMDD02/ST (self-test)

2. Turn the catches to lock the Emergency Module in place.

3. Connect the Live (brown) and Neutral (blue) input of the Emergency Module into the L1 and N of the Push-Wire terminal.

4. Connect the output of the Emergency Module to the socket on the driver marked ‘EME’.

Installation Features

BESA Box Mounting Position

The BESA Box mounting position is moulded to the center of the base of the fitting.

4 Pole Loop-in Loop-out Terminal

The Polo bulkhead comes with 4 pole loop-in loop-out Push-Wire Terminal.